Walk in interview lupin production-QC-Nagpur-30/12/18

emage


Interview questions and answer for pharmaceutical industry

Interview questions and answer for pharmaceutical industry:

We have provided interview questions for quality assurance in pharmaceutical industry here. There is no specified differences between quality control and quality assurance from interview point of view. They are all interlinked. But we tried to prepare in separate posts and produced. This post is an extension to our previous interview questions for quality assurance in pharmaceutical industry. If you attending an interview, you have to all these questions and answers in these 4 posts. It helps you a lot to face interview well.
Interview questions for quality assurance in pharmaceutical industry are as follows.
Qa-What do you know about change control?
Changes which were made to materials or procedures or methods or equipment or software should be documented properly. These changes should approved, validated and able to traceable. Change control deals and makes sure all these changes.

Explain about Bracketing and Matrixing study designs in stability testing/

Ans) These are the study designs for stability testing. In a full study design, you have to test the samples of all the design factors at all time points. Bracketing and Matrixing are reduced study designs.
When multiple design factors involved in a study, these are the best alternatives to full study design. If you use these designs, you need not to test all the samples at all time points. These study designs mostly used when multiple design factors involved.
Bracketing: In this schedule, At all time points only extremes of certain study factor (like container fill & or container size or strength etc) samples tested. Bracketing supposes that tested extremes stability represents the intermediate levels stability of that study factor.
Matrixing: In this schedule, at a specific time point a selected subset of the total number of possible samples for all factor combinations would be tested. At a next or subsequent time point, all the factor combinations for another subset would be tested. Matrixing supposes that at a given time point, tested each subset stability represents the all the samples stability.
Before using this study designs, certain assumptions should be evaluated and justified.
NOEL: No Observed Effect Level
MACO: Maximum Allowable Carry Over

CAPA:

Corrective Action and Preventive action. It’s an important part of QMS (Quality Management System). Corrective actions planned to know the cause of the problems which were happened in the past and correct it. Preventive actions intended to prevent the problems that might happen in the future.
Explain about Out of Specification (OOS) results and Out Of Expectation (OOE) results?
Out Of Specification (OOS) results: Analysed test result falling out side the predefined acceptance range or criteria made by company documentation or official compendia.
Out Of Expectation (OOE) results: Although the Analysed test result falls within the specification, this result will falls out side the procedure expected variability.
walkininterview 

Interview questions for quality assurance in pharmaceutical industry:

Stress Testing:

Also called as Forced degradation study, stress study. Forced degradation study intended to know the degradation products, it will helps us further to know the molecule intrinsic stability, degradation pathways establishment and to validate the molecule stability procedures. Stress testing conducted at the conditions which are more severe than the accelerated study conditions. For a formal stability program, stress testing not considered as a requirement. It is regulatory authority requirement.
What is the purpose/use(s) of stability testing?
Ans) Stability testing gives the confirmation as how the quality of study product changes with time.
It finds out the study product shelf life, recommended storage conditions as well as container closure system suability. Also gives assurance to the patient regarding stability of a drug product. Stability testing is a regulatory requirement also.

What are different types of stability studies along with its conditions?

Ans)
Long-term stability studies: Storage conditions 25+20C, 60+5% RH and Minimum Time period is 12 months
Intermediate stability studies: Storage conditions 30+20C, 60+5% RH and Minimum Time period is 6 months
Accelerated stability studies: Storage conditions40+20C, 75+5% RH and Minimum Time period is 6 months
Dead leg: Dead logs not allowed in water design systems. These are the stagnant areas with no water flow. It allows microbial contamination resulting the surface colonisation by forming biofilms. If a dead log present in any case, it should have particular pipe diameter and velocity. In general agreement in industry, dead log should not be more than the pipe diameter.
For e.g: If the pipe diameter is 5 cm , then dead log should not be more than 10cm.
Cleaning validation: It is a documented evidence involves the approved cleaning procedure for eliminating the process equipment contaminants. It means the process equipment ready and can be used safely for preparing the next product without any previous contaminants.
These contaminants may be chemical (previous product residues), microbial or Physical (Particulate matter) types. Different types of cleaning agents used in the cleaning validation like aqueous solvents (water, surfactants, acids or bases etc) and organic solvents.

Validation master plan (VMP):

It is a document describes the company’s validation strategy and approach for establishing the performance adequacy. VMP includes all the details and time scales regarding the validation work to be performed.
Process validation:
It provides a documented evidence assuring that a particular process produces a product with predetermined specifications and characteristics consistently.
Four types of process validation available.
Prospective validation: Conducted prior to process implementation to assuring that process is performs as intended on the basis of pre-planned plans.
Concurrent validation: Conducted during the product routine production.
Retrospective validation: Conducted on some products , those products which are already on commercial market. The intention is to establish the long term compliance of that product.
Re-validation: This is nothing but repetition of validation. Conducted to assuring that the changes/modifications done in equipment/process in according to the change control procedures. Those changes are not effecting the equipment/process and their produced products adversely.
https://walkininterview1.blogspot.com


12/21/18

akums interview production,QC,QA 23/12/18 Haridwar

akums interview production,QC,QA 23/12/18 Haridwar

Image may contain: 1 person

Acme Pharmaceuticals – Walk-Ins for Production / Packing / QC / QA / QC-Micro / Warehouse on 22nd Dec’ 2018

Acme Pharmaceuticals – Walk-Ins for Production / Packing / QC / QA / QC-Micro / Warehouse on 22nd Dec’ 2018
Company Name : Acme Pharmaceuticals

Job Type : Walk-In Interview
Greeting from Acme Pharmaceuticals Pvt. Limited (subsidiary of Zydus group )
Job opening for Production, Packing, Warehouse, QC/QA/QC Micro Officer / Executive., for Sanad Location
1)Department : Production
Post : Officer
Qualification : B. Pharm
Industry :- Pharmaceutical
Experience: 01-02 Years
Vacancy: 2
2)Department : Packing
Post: Officer
Qualification : B.Sc / B. Pharm
Industry:- Pharmaceutical
Experience: 01-02 Years
Vacancy: 1
Post: Plant Operator
Qualification: ITI (Operating of Brevity/ Vial washing/ Blister Pkg/ Labeling machine)
Industry:- Pharmaceutical
Experience: 02-03 Years
Vacancy: 8
3)Department: Warehouse
Post: Officer
Qualification: B. Com/ B.Sc (Knowledge of computer in SAP for material inward/outward)
Industry:- Any
Experience: 01-02 Years
Vacancy: 1
4)Department: QC/QA/QC Micro
Post: Officer/Executive
Qualification: B. Pharma/ B.Sc/ M. Sc Micro/ M. Pharm QA (Knowledge of HPLC/ QMS/ Documentation/ IPQA/ Microbiology)
Industry:- Pharmaceutical
Experience: 01-04 Years
Vacancy: 5
Interview Venue:
PF 61/62 GIDC Sanand-II,
Opp. Teva Pharma,
Opp. Chharodi Railway Station Sanand,
Ahmedabad
Walk-In Date: 22/12/18 (Saturday)
Apply Here :
Interested candidate can contact on: 6359203037 Or can send CV on: –
hr@acmepharma.in
/
pv.shah@acmepharma.in
{Monday to Saturday- 10:00am to 07:00pm only}

AVP/VP FOR GUJRAT LOCATION

No alt text provided for this image

Torrent pharma walk in interview 23/12/18 sikkim

zydus cadila walk in 23/12/18 ahmadabad

emage

12/15/18

production,QA,QC job vacancy at almak staff




Production,QA,QC job vacancies at almak staffing solution.
https://walkiniterview1.blogspot.com


emage

walk in interview whats apps group link

Hi all
walk in interview whats apps group link.
pharma job for fresher ,experienced candidates.QA,QC job,mechanical,electrical job,operator,officer,executive job.
below link:
https://chat.whatsapp.com/DzXuObPqkOHAEkeFC5u2cx
emage

11/6/18

interview question answers

Quality Assurance Interview Questions....

1. What is an SOP ?

A Standard Operating Procedure (SOP) is a certain type of document that describes in a step-by-step outline form how to perform a particular task or operation. Everyone in a company must follow the same procedures to assure that tasks are performed consistently and correctly. Most companies have a wide variety of SOPs that describe how to do different tasks. In many companies technicians and operators are trained in how to follow individual SOPs and their training record specifies which SOPs they are trained on and are authorized to use.

2. What is 21 CFR part 11 ?

Title 21 CFR Part 11 of the Code of Federal Regulations deals with the Food and Drug Administration (FDA) guidelines on electronic records and electronic signatures in the United States. Part 11, as it is commonly called, defines the criteria under which electronic records and electronic signatures are considered to be trustworthy, reliable and equivalent to paper records

3. What are user requirements?

User Requirements Specification describes what users require from the System. User requirement specifications are written early in the validation process, typically before the system is created. It is written by the System Owner and End Users, with input from Quality Assurance. Requirements outlined in the URS are usually tested in the Performance Qualification. User Requirements Specifications are not intended to be a technical document; readers with only a general knowledge of the system should be able to understand the requirements outlined in the URS.

4. What is a validation plan ?

Validation Plans define the scope and goals of a validation project. Validation plans are written before a validation project and are specific to a single validation project. Validation Plans can include:

   Deliverables (Documents) to be generated during the validation process

   Resources/Departments/Personnel to participate in the validation project

   Time-Line for completing the validation project

5. What is an IQ document ?

Installation Qualifications are a collection of test cases used to verify the proper installation of a System. The requirement to properly install the system was defined in the Design Specification. Installation Qualifications must be performed before completing Operational Qualification or Performance Qualification.

6. What is an OQ Document ?

Operational Qualifications are a collection of test cases used to verify the proper functioning of a System. The operational qualification tests requirements defined in the Functional Requirements. Operational Qualifications are usually performed before the system is released for use.

7. What is a PQ Document ?

Performance Qualifications are a collection of test cases used to verify that a System performs as expected under simulated real-world conditions. The performance qualification tests requirements that were defined in the User Requirement Specification (or possibly the Functional Requirements). Due to the nature of performance qualifications, these tests are sometime conducted with power users as the system is being released.

8. What is a Validation Summary Report ?

Validation Summary Reports provide an overview of the entire validation project. When regulatory auditors review validation projects, they typically begin by reviewing the summary report. The validation summary report should include:

   A description of the validation project

   All test cases performed, including if those test cases passed without issue

   All deviations reported, including how those deviations were resolved

 9. What is a Change Request ?

Change Control is a general term describing the process of managing how changes are introduced into a controlled System. In validation, this means how changes are made to the validated system. Change control is required to demonstrate to regulatory authorities that validated systems remain under control after system changes. Change Control systems are a favorite target of regulatory auditors because they vividly demonstrate an organization capacity to control its systems.

Q. Why water for pharmaceutical use is always kept in close loop in continuous circulation ?

A. Water is a best medium for many microorganisms, microorganism can be a highly pathogenic which causes serious diseases(many diseases are  water born), these pathogens infect after consumption of contaminated water, microorganisms tend to settle on a surface if water is allowed to stand in a stagnant position for few hours, these settled microorganism form a film over the surface of vessel and piping, such film formed by microorganisms is also called as biofilm, biofilms are very difficult of remove, once a biofilm is formed at a particular point then that point may form a biofilm again even after cleaning very easily as seed from this point is may not completely get removed effectively.

Biofilms then can become a source of microbial contaminations; therefore purified water after collection in a distribution system is always kept in a closed loop in a continuous circulation.

A continuous circulation is also not enough at some points, therefore it is aided with high temperature range from 65 °C to 80°C, a minimum temperature of 65 °C is considered a self sanitizing, but better assurance is obtained with a temperature of 80°C .

Purified water collected should be stored in a stainless still vessel which must facilitate distribution to the point of use in a closed loop of continuous circulation, tank should be made of corrosion free material of construction, and must facilitate sanitization and easy cleaning.

Q. Water for pharmaceutical use shall be free cations,anions and other impurities why ?

A.Water for pharmaceutical must be free from inorganic as well as organic impurities, minerals, and heavy metals. Some impurities like calcium, magnesium, ferrous are responsible for degradation of drug molecule, many cations like ferrous and calcium magnesium act as catalysts in degradation reaction of drug molecule, anions like chloride are highly active they participate in nucliophylic substitution reactions, where in they break a double bond between -C=C- in to a single bond as CL –CH-CH2- , which a reason why we observe that color dies tend to fed in presence of chlorine as most of the dies used are diazo compounds which has plenty of places for nucliophylic substitution reactions, which is also a reason why stability of drug is drastically affected in presence of cations and anions from mineral origin present in water.

Q. Water for pharmaceutical use shall be free heavy metals why ?

A. Heavy metals like lead and arsenic are highly cumulative neurotoxic metals, heavy metals are not eliminated out of our body easily like other drugs and molecules but heavy metals bind with proteins and tend to get accumulated in fatty tissues, nerve tissue is most likely to get damaged by heavy metals, heavy metal causes nervous tissue damage there for water must be free from heavy metals.

Q. Brazil falls under which climatic zone ?

A. Zone IVB (30 degree celsius and 75% relative humidity)

Q. Change in the size or shape of the original container requires any stability study?

A. Change in the size or shape of the original container may not necessitate the initiation of new stability study.

Q. Forced degradation(stress testing) and accelerated stability testing are same?

A. Forced degradation and stress testing are not same. Stress testing is likely to be carried out on a single batch of the drug substance. The testing should include the effect of temperatures (in 10°C increments (e.g., 50°C, 60°C) above that for accelerated testing), humidity (e.g., 75 percent relative humidity or greater) where appropriate, oxidation, and photolysis on the drug substance. The testing should also evaluate the susceptibility of the drug substance to hydrolysis across a wide range of pH values when in solution or suspension. Photo stability testing should be an integral part of stress testing.

Q. According to WHO guidelines what is the storage condition of climatic zone IVa and zone IVb?

A. Zone IV a: 30°C and 65% RH (hot and humid countries)

Zone IV b: 30°C and 75% RH (hot and very humid countries

Q. Countries comes under climatic zone IVb?

A.Brazil,Cuba,China,Brunei,Cambodia,Indonesia,Malaysia,Myanmar,Philippines,Singapore,Thailand

Q. What is the purpose of stress testing in stability studies?

A. Stress testing of the drug substance can help identify the likely degradation products, which can in turn help establish the degradation pathways and the intrinsic stability of the molecule and validate the stability indicating power of the analytical procedures used. The nature of the stress testing will depend on the individual drug substance and the type of drug product involved.

Q. What is the formula for calculating number of air changes in an area?

A. Number of air changes/hour in an area is

           = Total Room Airflow In CFM x 60

           Total Volume of room in cubic feet

For calculating Total Room Airflow in CFM, first calculate air flow of individual filter. Formula is given below.

Air flow (in cfm) = Avg.air velocity in feet/Minute x Effective area of filter                         

Then find Total air flow. Formula is

Total Air flow = Sum of air flow of individual filter.

Air flow Velocity can be measured with the help of Anemometer.

Q. What is dead leg?

A. A dead leg is defined as an area in a piping system where liquid can become stagnant and not be exchanged during flushing.

Q. What is the recommended bio burden limits of purified water & WFI?

A. Purified water has a recommended bioburden limit of 100 CFU/mL, and water for injection (WFI) has a recommended bio burden limit of 10 CFU/100 mL.

Q. Brief about ICH stabilty guidelines?

A. Q1A- Stability testing of new drug substance & products

Q1B- Photo stability testing of new drug substances & products

Q1C-Stability testing of new dosage forms

Q1D-Bracketing & Matrixing designs for testing of new drug substances and products

Q1E-Evaluation of stability data

Q1F-Stability data package for registration applications in climatic zone III & IV (Withdrawed)

Q. What is significant changes in stability testing?

A.1. A 5% change in assay for initial value.

2. Any degradation products exceeds its acceptance

    criterion.

3. Failure to meet acceptance criterion for

    appearance,physical artributes and functionality

     test.

4. Failure to meet acceptance criteria for dissolution

    for 12 units.

Q. If leak test fail during in process checks what needs to be done ?

A.Immediately stop packing process and check for

1.Sealing temperature               

2.Verify for any possible changes like foil width,knurling etc.

3.Check & quarantine the isolated quantity of packed goods from last passed inprocess.

4.Collect random samples & do retest.

5.Blisters from the leak test passed containers shall allow to go further and rest must be deblistered/defoiled accordingly.

Q. How many Tablets shall be taken for checking friability?

A. For tablets with unit mass equal or less than 650 mg, take sample of whole tablets corresponding to 6.5g.For tablets with unit mass more than 650mg,take a sample of 10 whole tablets.

Q. What is the formula for calculating weight loss during friability test?

A. %Weight loss = Initial Weight - Final Weight  X 100

                         Initial Weight

Q. What is the pass or fail criteria for friability test?

A. Generally the test is run for once.If any cracked,cleaved or broken tablets present in the tablet sample after tumbling,the tablets fails the test.If the results are doubtful,or weight loss is grater than the targeted value,the test should be repeated twice and the mean of the three tests determined.A  mean weight loss from the three samples of not more than 1.0% is considered acceptable for most of the products.

Q. What is the standard number of rotations used for friability test?

A. 100 rotations   

Q. What is the fall height of the tablets in the friabilator during friability testing?

A. 6 inches.Tablets falls from 6 inches eight in each turn within the apparatus.

Q. Why do we check hardness during inprocess checks?

A. To determine need for the pressure adjustments on the tableting machine. Hardness can affect the disintegration time.If tablet is too hard, it may not disintegrate in the required period of time. And if tablet is too soft it will not withstand handling and subsequent processing such as coating,packing etc.

Q. What are the factors which influence tablet hardness?

A.        1.compression force

     2.Binder quantity(More binder more hardness)

     3.Moisture content

Q. Which type of tablets are exempted from Disintegration testing?

A. Chewable Tablets

Q. Which capsule is bigger in size - size '0' or size '1'?

A. '0' size

Q. What is the recommended temperature for checking DT of a dispersible tablet?

A. 25 ±10C (IP) & 15 – 250C (BP)

Q. What is mesh aperture of DT apparatus ?

A. 1.8 -2.2mm (#10)

Q. What is the pass/fail criteria for disintegration test?

A. If one or two tablets/capsules fails to disintegrate completely, repeat the test on another 12 additional dosage units. The requirement is meet if not fewer than 16 out of 18 tablets/capsules tested are disintegrated completely.

Q. What is the recommended storage conditions for empty hard gelatin capsules?

A. 15 - 250C & 35 -55% RH

Q. Which method is employed for checking “Uniformity of dosage unit”?

A.A.)Content uniformity

B.)    Weight Variation

Weight variation is applicable for following dosage forms;Hard gelatin capsules,uncoated or film coated tablets,containing 25mg or more of a drug substance comprising 25% or more by weight of dosage unit.

Q. What is the recommended upward and downward movement frequency of a basket-rack assembly in a DT apparatus?

A.  28 – 32 cycles per minute.

Q. When performing the ‘uniformity of weight’ of the dosage unit, how many tablet/capsule can deviate the established limit?

A. Not more than two of the individual weights can deviates from the average weight by more than the percentage given in the pharmacopeia,and none can deviates more than twice that percentage.

Weight Variation limits for Tablets

     

IP/BP

Limit     

USP

80 mg or less

10%

130mg or less

More than 80mg or Less than 250mg

7.5%

130mg to 324mg

250mg or more

5%

More than 324mg

Weight Variation limits for Capsules

IP

Limit

Less than 300mg

10%

300mg or More

7.5%

Q. What needs to be checked during inprocess QA checks?

A.

a.) Environmental Monitoring

b.) Measured values obtained from the process equipment  (ex:temperature,RPM etc.)

c.) Measured values obtained from persons (ex:timmings,entries etc.)

d.) Process attributes (Ex:weight,hardness,friability etc.)

Q. What precautions shall be taken while collecting  inprocess samples ?

A. While collecting inprocess samples, avoid contamination of the product being sampled (Don’t collect samples with bare hands) & avoid  contamination of sample taken.

Q. In a tablet manufacturing facility ‘positive’ pressure is maintained in processing area or service corridors?

A. In tablet manufacturing facilities, pressure gradients are maintained to avoid cross contamination of products through air. Usually processing areas are maintained under positive pressure with respect to service corridors.

Q. If sticking observed during tablet compression what may the probable reason for the same?

A.1.If the granules are not dried properly sticking can

    occur.

2.Too little or improper lubrication can also leads to

    sticking.

3.Sticking can  occur because of too much binder or

   hygroscopic granular.

Q. What checks shall be carried out, while calibrating  DT apparatus?

A. While calibrating DT apparatus, following checks shall be performed.

1.)       Number of strokes per minute (Limit:29-32 cycles/min)

2.)       Temperature by probe & standard thermometer

           (Limit: 37 ± 1 OC).

    3).   Distance travelled by basket (Limit:53 -57mm)

Q. What is In process checks?

A. In process checks are  checks performed during an activity,In order to monitor and,if necessary,to adjust the process to ensure that product confirms to its specification.

Q. What is the difference between disintegration and dissolution?

A. Disintegration is a disaggregation process, in which an oral dosage form falls apart in to smaller aggregates.(Disintegration time is the ‘break up’ time of a solid dosage form).

Where as dissolution is a process by which solid substance enters in the solvent to yield a solution.It is controlled by the affinity between the solid substance and the solvent.

In other word disintegration is a subset of dissolution.

Q. Why do we calibrate a qualified equipment/instrument on definite intervals?

A. An equipment or instrument can ‘drift’ out of accuracy between the time of qualification and actual use.So it is recommended to calibrate and recalibrate the measuring devices and instruments on predetermined time intervals, to gain confidence on the accuracy of the data.

Q. Why do we consider three consecutive runs/batches for process validation? Why not two or four?

A. The number of batches produced in the validation exercise should be sufficient to allow the normal extent of variation and trends to be established and to provide sufficient data for evaluation and reproducibility.

·       First batch quality is accidental (co-incidental),

·       Second batch quality is regular (accidental),

·       Third batch quality is validation(conformation).

In 2 batch we cannot assure the reproducibility of data,4 batches can be taken but the time and cost are involved.

Q. Explain about revalidation criteria of AHU system?

A. AHU system shall be revalidated periodically as mentioned in the regulatory standards. AHU shall be revalidated in following cases also.

·       When basic design of AHU is changed,

·       When clean room volume is changed,

·       When new equipment is installed

·       When a construction is carried out, that calls for reconstruction of AHU system.

Q. What needs to be checked during AHU validation?

A. During AHU validation, following tests shall be carried out

·       Filter efficiency test,

·       Air velocity & number of air changes,

·       Air flow pattern (visualization)

·       Differential pressure, temperature and RH

·       Static condition area qualification

·       Dynamic condition qualification

·       Non-viable count

·       Microbial monitoring

·       Area recovery and power failure study.

Q. Position of oblong tablets to be placed in hardness tester to determine the hardness? Lengthwise / widthwise?

A. Position of oblong tablets should be length wise because the probability of breakage is more in this position.

Q. Explain in detail about qualification of pharmaceutical water system?

A. Qualification of pharmaceutical water system involves three phases

·       Phase -1

·       Phase -2

·       Phase -3

Phase -1

A test period of 2-4 weeks should be spent for monitoring the system intensively. During this period the system should operate continuously without failure or performance deviation.Water cannot be used for pharmaceutical manufacturing in this phase.The following should be included in testing approach.

·       Under take chemical & microbiological testing in accordance with a defined plan.

·       Sample incoming feed water daily to verify its quality.

·       Sample each step of purification process daily.

·       Sample each point of use daily.

·       Develop appropriate operating ranges.

·       Demonstrate production and delivery of product water of required quantity and quality.

·       Use and refine the SOP’s for operation,maintenance,sanitization and trouble shooting.

·       Verify provisional alert and action levels.

·       Develop and refine test failure procedure.

Phase -2

A further test period of 2-4 weeks. Sampling scheme will be same as  Phase – 1.Water can be used for manufacturing process in this phase.

Approach should also

·       Demonstrate consistent operation within established ranges.

·       Demonstrate consistent production & delivery of water of required quality and quantity.

Phase - 3

Phase 3 runs for one year after satisfactory completion of phase-2.Water can be used for manufacturing process during this process.

Objectives & Features of Phase -3

·       Demonstrate extensive reliable performance.

·       Ensure that seasonal variations are evaluated.

·       The sample locations, sampling frequencies and test should be reduced to the normal routine pattern based on established procedures proven during Phase -1 & phase - 2.

Q. What are the recommended environmental monitoring limits for microbial contamination?

Q. What is the difference between calibration and Validation?

A. Calibration is a demonstration that, a particular Instrument or device produces results with in specified limits by comparisons with those produced by a reference or traceable standard over an appropriate range of measurements.

Where as Validation is a documented program that provides high degree of assurance that a specific process, method or system consistently produces a result meeting pre-determined acceptance criteria.

In calibration performance of an instrument or device is comparing against a reference standard. But in validation such reference standard is not using.

Calibration ensures that instrument or measuring devices producing accurate results. Whereas validation demonstrates that a process, equipment, method or system produces consistent results (in other words, it ensures that uniforms batches are produced).

Q. Briefly explain about ICH climatic zones for stability testing & long term storage conditions?

A.ICH STABILITY ZONES

Zone

Type of Climate

Zone I

Temperate zone

Zone II

Mediterranean/subtropical zone

Zone III

Hot dry zone

Zone IVa

Hot humid/tropical zone

Zone IVb

ASEAN testing conditions hot/higher humidity

Long term Storage condition

Climatic Zone

Temperature

Humidity

Minimum Duration

Zone I

21ºC ± 2ºC

45% rH ± 5% rH

12 Months

Zone II

25ºC ± 2ºC

60% rH ± 5% rH

12 Months

Zone III

30ºC ± 2ºC

35% rH ± 5% rH

12 Months

Zone IV

30ºC ± 2ºC

65% rH ± 5% rH

12 Months

Zone IVb

30ºC ± 2ºC

75% rH ± 5% rH

12 Months

Refrigerated

5ºC ± 3ºC

No Humidity

12 Months

Frozen

-15ºC ± 5ºC

No Humidity

12 Months

Q. What is bracketing & matrixing in  stability testing?

A.Both Matrixing & Bracketing’s are reduced stability testing designs

Bracketing

The design of a stability schedule, such that only samples of extremes of certain design factors (ex:strength,package size) are tested at all time points as in full design.The designs assumes that the stability of any intermediate level is represented by the stability of extremes tested.

Matrixing

The design of a stability schedule, such that a selected subset of possible samples for all factor combinations is tested at a specified time point.At a subsequent time point another subset of samples for all factor combination is tested.The design assumes that the stability of each subset samples tested represents the stability of all samples at a given time point.

There for a given time point other than initial & final ones not every batch on stability needs to be tested.

Q.What are the common variables in the manufacturing of tablets?

A.·       Particle size of the drug substance

·       Bulk density of drug substance/excipients

·       Powder load in granulator

·       Amount & concentration of binder

·       Mixer speed & mixing timings

·       Granulation moisture content

·       Milling conditions

·       Lubricant blending times

·       Tablet hardness

·       Coating solution spray rate

Q. Whether bracketing & validation concept can be applied in process validation?

A.Both Matrixing & Bracketing’s can be applied in validation studies.

Matrixing

Different strength of same product

Different size of same equipment

Bracketting - Evaluating extremes 

Largest and smallest fill volumes

Fastest and slowest operating speeds

Thanking you.